Home / Guides / Daikin air conditioner error codes
Daikin air conditioner error codes
When a Daikin unit stops and the operation lamp blinks, it has stored an error code. Here is how to read it with the remote and what the official Daikin codes mean.
How to show the code with the remote
- Point the remote at the indoor unit and hold the Cancel button (on some remotes ON TIMER CANCEL or OFF TIMER CANCEL) for about 5 seconds, until 00 blinks on the remote display.
- Press Cancel again, one short press at a time. The remote steps through the codes and the indoor unit beeps at each one.
- Stop when you hear a long, continuous beep: the code shown on the remote at that moment is the active fault.
- Hold Cancel for 5 seconds to leave. The display also clears itself after a minute without presses.
00 means normal. The procedure and the codes can differ slightly between models: your unit’s manual is the final word.
Daikin error code list
| Code | Where | Meaning |
|---|---|---|
| U0 | System | Refrigerant shortage |
| U2 | System | Supply voltage drop or main circuit overvoltage |
| U4 | System | Transmission failure between the indoor and outdoor unit |
| UA | System | Indoor and outdoor unit combination fault |
| A1 | Indoor | Indoor circuit board (PCB) fault |
| A5 | Indoor | Freeze‑up protection |
| A6 | Indoor | Indoor fan motor fault |
| C4 | Indoor | Heat exchanger temperature sensor fault |
| C9 | Indoor | Suction (room) air temperature sensor fault |
| E1 | Outdoor | Circuit board fault |
| E5 | Outdoor | Compressor overload protection (OL) activated |
| E6 | Outdoor | Compressor start‑up fault |
| E7 | Outdoor | DC fan motor fault |
| E8 | Outdoor | Input overcurrent |
| F3 | Outdoor | Discharge pipe high‑temperature control |
| F6 | Outdoor | High‑pressure control (in cooling) |
| H0 | Outdoor | Sensor fault |
| H6 | Outdoor | Stopped by a faulty position‑detection sensor (compressor) |
| H8 | Outdoor | DC current sensor fault |
| H9 | Outdoor | Outdoor air (suction) temperature sensor fault |
| J3 | Outdoor | Discharge pipe temperature sensor fault |
| J6 | Outdoor | Heat exchanger temperature sensor fault |
| L3 | Outdoor | Electrical parts overheating |
| L4 | Outdoor | Inverter heatsink high temperature |
| L5 | Outdoor | Output overcurrent |
| P4 | Outdoor | Inverter heatsink temperature sensor fault |
What you can check yourself
- Any code: switch the unit off at the breaker, wait a few minutes and switch it on again. If a breaker had tripped, have the installation checked before resetting it repeatedly.
- A5 (freeze‑up): often caused by poor airflow. Clean the indoor filters and make sure nothing blocks the air inlet and outlet.
- Outdoor codes such as E5, F3, F6, L4: check that the outdoor unit is not in a closed space, covered or blocked by plants, and that its fins are not clogged.
- U4 right after installation or work on the system: call the installer; it usually concerns the cable between the two units.
Sensor, circuit board, refrigerant and compressor codes need a qualified technician. Do not open the unit yourself.
Can a phone app read the error code?
No. Infrared is one‑way: the remote, or a phone with an IR blaster, sends commands but never receives anything from the unit. The code shows on the original Daikin remote or on the unit itself. A phone app such as acbee can still replace a lost Daikin remote for everyday control.
Sources
- Daikin India — Error codes (code list)
- Daikin Malaysia — Error codes (how to read them with the remote)